PRO PLM Installation Instructions
Avoid mounting components or routing wires near
hot surfaces
Avoid mounting components or routing wires near
moving parts
Tape or loom wires under hood for protection and
appearance
Use grommets when routing wires through metal
surfaces
Use a Digital Multi Meter for testing and verifying
circuits. DO NOT USE A TEST LIGHT, OR
"COMPUTER SAFE PROBE" as these can set off air
bags or damage vehicle computers.
PROFESSIONAL INSTALLATION STRONGLY RECOMMENDED
Installation Precautions:
Roll down window to avoid locking keys in vehicle
during installation
FCC COMPLIANCE
This device complies with Part 15 of the FCC rules and with RSS-210 of Industry Canada.
Operation is subject to the following two conditions:
1. This device may not cause harmful interference, and
2. This device must accept any interference received, including any interference that may
cause undesired operation.
Warning! Changes or modifications not expressly approved by the party responsible for
compliance could void the user’s authority to operate the equipment.
Technical Support (800) 225-6074
or go to
http://techservices.audiovox.com
Zobrazit stránku 0
1 2 3 4 5 6 ... 23 24

Shrnutí obsahu

Strany 1 - Installation Precautions:

1PRO PLM Installation InstructionsAvoid mounting components or routing wires nearhot surfacesAvoid mounting components or routing wires nearmoving par

Strany 2 - PRO PLM SYSTEM LAYOUT

101. 8 PIN MAIN HARNESSBLACK - Chassis Ground Source (-)Connect the BLACK wire to a solid chassis ground point using a ring terminal and self tapping

Strany 3

111. 8 PIN MAIN HARNESS, CONTINUEDBROWN - Negative Door Input (-)Locate the vehicle’s dome light or door pin switch wire.Verification: This wire will

Strany 4

122. 6 PIN HARNESS, CONTINUEDDK BLUE - Trunk Release Output (-) This wire provides a 500mA negative output capable of driving relays. For Contro

Strany 5

134. 3 PIN DOOR LOCK HARNESSRED - Lock Output (-)GREEN - Unlock Output (-)RED/BLACK - 2nd Door Unlock OutputNegative Switching and Negative Switching

Strany 6 - LOT MODE PROGRAMMING GUIDE

14RED - Lock Output (-)GREEN - Unlock Output (-)RED/BLACK - 2nd Door Unlock OutputPositive Switching and Positive Switching with 2-step unlock feature

Strany 7

15RED - Lock Output (-)GREEN - Unlock Output (-)RED/BLACK - 2nd Door Unlock OutputOne Wire Negative Multiplexed and One Wire Negative Multiplexed with

Strany 8

16RED - Lock Output (-)GREEN - Unlock Output (-)RED/BLACK - 2nd Door Unlock OutputOne Wire Positive Multiplexed and One Wire Multiplexed With 2-step U

Strany 9 - ON BOARD SHOCK SENSOR

17RED - Lock Output (-)GREEN - Unlock Output (-)RED/BLACK - 2nd Door Unlock OutputReverse Polarity (5-Wire Door locks) and Reverse Polarity with 2-ste

Strany 10 - 1. 8 PIN MAIN HARNESS

18RED - Lock Output (-)GREEN - Unlock Output (-)RED/BLACK - 2nd Door Unlock OutputAdding Door ActuatorsAfter installing door actuators, (not supplied)

Strany 11 - 2. 6 PIN HARNESS

195. ACCESSORY CONNECTORS6 Pin Override Push-Button and LEDThe status LED / override button should be mounted in a visible and easily accessible loca

Strany 12 - 3. 5 PIN HARNESS

2PRO PLM SYSTEM LAYOUTBLACK GROUNDYELLOW IGNITIONPURPLE DOOR TRIGGER (+)RED PARKING LIGHT INPUTWHITE PARKING LIGHT OUTPUTBROWN DOOR TRIGGE

Strany 13 - Negative Locks:

207. System Testing1. Follow each instruction below.2. Verify that the system operates as indicated under each instruction. Refer to the system owner

Strany 14 - Positive Locks:

21Press DISARM:1. Doors unlock.2. Factory alarm (if equipped) is turned off.3. Siren/horn sounds once/ parking lights flash once.4. Courtesy lights tu

Strany 15 - Multiplex Locks:

22 ITS IntroductionThe PRO PLM may be used as a ITS (Interior Theft Sensor) and when doing so it is designed to honk the horn if alight impact is de

Strany 16

23ITS LAYOUTBLACK GROUNDYELLOW IGNITIONPURPLE DOOR TRIGGER (+)RED N/AWHITE N/ABROWN DOOR TRIGGER (-)RED/WHITE +12 VOLT BATTERYORANGE N

Strany 18

3SETUP & PROGRAMMING - CONSUMER MODEConsumer Mode Transmitter Programming Bank1. Turn the ignition ON.2. Press and release the override button 3

Strany 19 - 5. ACCESSORY CONNECTORS

4Transmitter Programming BankFeature Programming Bank 1 LED Flash 2 LED Flashes 3 LED Flashes1. Security Function ON OFF2. Passive Locks Passive Activ

Strany 20 - 6. SYSTEM POWER-UP PROCEDURE

5SETUP & PROGRAMMING - LOT MODELot Mode Transmitter Programming Bank - ACM Transmitter1. Turn the ignition ON.2. Press and release the override

Strany 21 - SYSTEM TESTING, CONTINUED

6Transmitter Programming BankFeature Programming Bank 1 LED Flash 2 LED Flashes 3 LED Flashes1. Security Function ON OFF2. Passive Locks Passive Activ

Strany 22 - ITS FUNCTIONALITY

7Transitioning into Lot Mode - ACM Transmitter1. Turn the ignition ON.2. Press and release the override button 3 times.3. The system will chirp 1 t

Strany 23 - ITS LAYOUT

8Transitioning into Factory Keyless Upgrade Mode - BLUE1. Open a vehicle door.2. Enter the vehicle number into an ACM keypad.3. Press the UNLOCK bu

Strany 24

9Transitioning into Lot Mode1. Turn the ignition ON.2. Press and release the override button 3 times.3. The system will chirp 1 time.4. Press butt